- Product Description
-
Order Data
Specification
Order No. CTSC-200 CPU224XP, 72KB Program Memory/10KB Data Memory,14DI*10DO,24VDC Power Supply,Transistor output,2AI/1AQ,2*PPI/FPORT,1*Ethernet port CTS7 214-2AD41-0324
- Technical Spec
-
1
224XP integrate 1*Ethernet port;
2
Equipped with Analog expansion board(Addressing mode:AIW addressing);
3
Optional expansion board:Support CAN and 4AI/2AQ expansion board;
4
Compatible Siemens expansion module;
5
COTRUST 224XP program memory up to 72KB(S7-200 224XP program memory 16KB);
6
High-speed counter:6*30KHz single phase or 4*20KHz AB phase;
7
High-speed pulse output:2*50KHz;
8
Programming software use MagicWorks PLC V2.12 and Micro WIN.
Performance Parameters
Physical Features
Dimension(W×H×D)
137×80×62mm
Power dissipation
7W
Memory Features
Program memory
24KB,can be expand to 72KB
Data memory
10KB,can be expand to 110KB
Power-off protection time(super capacitor )
112 hours(typical)
External battery (Optional)
200 days(typical)
General Features
Counters total 256(super capacitor backup)
Internal memory bits
256(super capacitor backup)
Stored permanently on power down
112 hours(typical)
Time Interrupts
2 with 1ms resolution
Edge Interrupts
4 rising edges and/ or 4 falling edges
Analog adjustment
2 with 8 resolution
Boolean execution speed
0.15µs
Float execution speed
8µs
Clock
Embedded
Rated voltage
220VAC
Power supply
Native and extended bus+5V
+5V
+24V
1A
10mA
300mA
Integrated Communication Function
Communication port
2 communication ports ,PORT0:PPI/Free port,RS485;FPORT1:PPI/freeport, RS485 PWL
PPI baud rates(baud)
9.6k、19.2k and187.5k
Freeport baud rates (baud)
1.2k ~ 115.2k
Maximum cable length per segment
Isolated repeater applied
Isolated repeater unapplied
When it is 1000 m, baud rate is 187.5k; when it is 1200 m, 38.4k.
50 m
Maximum number of stations
32 stations per segment,126 stations per network
Maximum number of masters
32
Point to point (PPI Master Mode)
Yes(NWTR/NETW), 8 total, 2 reserved
Ethernet Function
Communication port
1 Ethernet port
Communication standard
IEEE802.3 standard
Communication speed
10Mbps and 100Mbps self-adaption
Adaptive cross connection
Non support
Interface to industrial Ethernet(10/100Mbps)
RJ45
Protocol type
UDP/TCP protocol
Support MICO Ethernet programming, support Ethernet communication between PLC.
Collocation method
Support the upper computer through the Ethernet port search PLC, support the mouth download system configuration.
Max Connections
Each PLC supports up to 8 UDP connections and up to
4 TCP connections.
The maximum number of IT connections
8 UDP_PPI connections, with 4 master stations and 4 slave stations.
4 ModBus_TCP connections, 2 master stations and 2 slave stations.
User data number
Up to 200 bytes are used for TCP/IP transmission.
Up to 240 bytes are used for ModBus_TCP transport.
Port
local:1~65535
remote server:8888
Boot time or restart time after reset
3 seconds
Indicator lamp
Green RMC indicator: on: remote control in effect, off: remote control out
Green Ethernet indicator: on: connection, flicker: transmission; out: not connected
Maximum cable length
100m
Isolation
Communication port
I/O Feature
Number of integrated digital inputs
14
Input type
Sink/Source
Number of integrated digital outputs
10
Output type
Relay dry contact
Digital I/O mapping domain
640DI/640DQ
Analog I/O mapping domain
194AI/194AQ
Maximum number of expandable I/O modules
7
Pulse catch inputs
14
High-speed counters
Total
Uniphase counters
Bi-phase counters
6
6×30KHz
4×20KHz
Digital Input Features
Number of integrated digital input
14
Input type
Sink/ Source
Rated voltage
24V DC
Input voltage range
20.4~28.8V DC
Surge voltage
35V DC,continuously 0.5s
Logical 1 Signal (minimum)
Logical 0 Signal (Maximum )
15 VDC,2.5mA
5 VDC,1mA
Connect 2 wire proximity switch sensor (BERO)
Allowable leakage current (maximum)
1mA
Input filter
support 0.2ms,0.4ms,0.8ms,1.6ms,3.2ms,6.4ms,12.8ms,default 6.4ms
Isolation(field side to logical circuit)
Isolation groups
500V AC,1min
refer to wiring diagramSimultaneous input
14
Maximum cable length
Shielded
Unshielded
500 M(standard input)
50 M(high-speed counters input)
300 M(standard input)
Digital Output Features
Number of integrated digital output
10
Output type
Relay dry contact
Rated voltage
DC:24V,AC:110V/220V
Output voltage range
DC:5~30V,AC:5~250V
Output current (Max)
2A
Surge current
5A,4s@10% duty ratio
Lamp load
DC:30W /AC:200W
On resistance
Max 0.2Ω
Input delay
Max 10ms
Switching frequency(Max)
Resistive load :10Hz
Lamp load:1Hz
Inductive load:0.5Hz
Mechanical life cycle
10,000,000
Contact endurance
100,000
Simultaneous output
10
Parallel output
Only when the outputs are in the same group
Maximum cable length
Shielded
Unshielded
500m
150m
- Installation
-
Wiring diagram
RS485 communication port definition
Connector
Pin
PORT1(RS485)
PORT0(RS485)
1
Shell Grounded
Shell Grounded
2
+24V Grounded
+24V Grounded
3
RS485+signal B
RS485+signal B
4
Send the application
Send the application
5
+5V Grounded
+5V Grounded
6
+5V,100Ω
+5V,100Ω
7
+24V
+24V
8
RS485-signal A
RS485-signal A
9
NC
NC
Shell
Shell Grounded
Shell Grounded