product_Banner

H31-01 CPU

High cost performance CPU

Order No.:CTH3 H31-000S1

Specification:H31-00:192KB+64KB PM,512KB DM,16KB DM when power down,2*PPI port,1*TCP/IP MODBUS port.1*USB port.Support uni axial motion control.Support interpolation (line and arc),Support electronic CAM and electronic gear.The maximum number of racks is 1.

Product Description

Order Data

Model No.

Series

Specification

Order No.

H31-00

CTH-300

H31-00,192KB+64KB PM,512KB DM,16KB DM when power down,2*PPI port,1*TCP/IP MODBUS port.1*USB port.Support uni axial motion control.Support interpolation (line and arc),Support electronic CAM and electronic gear.The maximum number of racks is 1.

CTH3 H31-000S1


Technical Spec

Performance Parameters

Physical Features
Dimension(W×H×D)34 x 115 x 101.6mm
Power dissipation19.2W


SeriesMotion Control Thin CPU
Model no.H31-00
Order no.CTH3 H31-000S1
Bit instruction processing time 0.086us/step
Floating-point instruction processing time1.4us/step
User program memory192KB+64K
Data memory512KB
Power down permanently maintains data memory16KB
Power down keep mode FlashROM
System indicator 7
RUN/STOP dialing codeYes,2 states
Analog potentiometerNo
Real-time clock Built in
Battery card interfaceNo


Data area and retention features
Data area typeSizeAddressing rangeAddressing propertyAccess propertyHold property
Digital volume  (I) 256bytesIB0-IB255Read/writeImmediate access/direct access/indirect accessPower down hold data are not supported
Digital volume(Q)256bytesQB0-QB255Read/writeImmediate access/direct access/indirect accessPower down hold data are not supported
Analog volume (AI)1024bytesAIW0-AIW1022Only writesImmediate access/direct access/indirect accessPower down hold data are not supported
Analog volume (AQ)1024bytesAIW0-AIW1022Only writesImmediate access/direct access/indirect accessPower down hold data are not supported
Variable memory(V)65536bytesVB0-VB65535Read/writeDirect access/indirect accessVB0-VB10239 Power down hold data
Special memory area(SM)2048bytesSMB0-SMB2047SMB0-SMB29 Read/writ/SMB30-SMB2047 Read/writDirect access/indirect accessPower down hold data are not supported
Bit memory(M)32bytesMB0-MB31Read/writeDirect access/indirect accessPower down hold data
Local Variable(L)128bytesLB0-LB127Read/writeDirect accessStartup to stop the same call position subroutine can be keep,power down hold data are not supported
Accumulator register(AC)4AC0-AC3Read/writeDirect accessPower down hold data are not supported
Step register (S)32bytesSB0-SB31Read/writeDirect access/indirect accessPower down hold data are not supported
Timers (T)1ms*36
10ms*752
100ms*1260
T0-T2047Timing registers can be directly/indirectly accessed, the status bit can only be directly accessedThe current count value can be power down hold data, the status bit can not be hold
Counter(C)2048C0-C2047Timing registers can be directly/indirectly accessed, the status bit can only be directly accessedThe current count value can be power down hold data, the status bit can not be hold
Data Block(DB)512KBRead/writeDirect access/indirect access16KB Power down hold data


LED indicator characteristics
24V power indicatorGreenON = 24VDC power supply normal, OFF = no 24VDC power supply
SF indicatorRedON = system failure, OFF = no error
BF indicatorRedON = bus fault, OFF = no error
FRCE indicatorYellowON = coercion of an item, OFF = NO coercion of an item (can also be controlled through the FLC command)
RMC indicatorGreenON: CPU has successfully communicated with the remote server (dialing switch 3 is ON and Ethernet communication port parameters have been correctly configured)
OffOFF:CPU fails to communicate with the remote server or disallows communication with the remote server (allows and disallows communication with the server via dialing switch)
RUN indicatorGreenON = system running, OFF = system stop
STOP indicatorOrangeON = system stop, OFF = system running
EtherNET  indicatorGreenON = connected, OFF = disconnected
YellowON = 100Mbps,OFF = 10Mbps
EtherCAT indicatorGreenON = connected, OFF = disconnected
YellowON = 100Mbps,OFF = 10Mbps
Expand I/O capabilities
IO expandMaximum number of racks of 1CPU1
Maximum number of modules supported per rackSupport up to 8 modules except  power, CPU, relay module


Integrated communication function


Port numberEthernet port:1
Serial port:2(RS485)
USB:1
EtherNET communication portCommunication port1*EtherNET port
Baud rate10/100Mbps adaptive
Protocol types

Support UDP_PPI protocol, Modbus_TCP /IP master and slave protocol, support Socket free programming, support Ethernet programming and Ethernet communication between CPU

Maximum length of each cable100m  directly connected
The maximum number of connections per siteUDP_PPI supports a maximum of 8 connections, modbus_TCP supports a maximum of 32 connections, Socket supports a maximum of 4 connections, 2 UDP, 2 TCP
Quantity of user data

Up to 200 bytes for UDP_PPI transfer,

Up to 240 bytes for ModBus_TCP transmission,

A maximum of 512 bytes are used for Socket transmission

DHCP functionSupport
Remote monitoring/programming Support
Isolation

Communication port isolation

Serial port(RS485)communication port 2 PPI/ free port switchable port, with 24VDC output
Data transfer ratePPI/MPI:9.6K/19.2K/187.5K
Free port::1.2K-115.2K
Maximum number of stations32 for each segment and 126 for each network
Maximum number of master stations 32
Point-to-point (PPI master mode)Yes (NETR/NETW), with a maximum of 8 connections, each connection communicating a maximum of 200 bytes
MPI connections (1PG/1OP)8,with 2 reserved
Maximum cable length per segmentUsing isolation repeater: 1000m at 187.5kbps and 1200m at 38.4kbps
No isolation repeater used:50m
IsolationCommunication port isolation
CPU and USB interface specificationInterface formUSB A type female port
Programmable card mediaUSB flash drive
Download /upload feature Support
Formulation functionSupport
Data record archiving functionSupport


CANopen function
CANopenCommunication module CANopen module 
Maximum number of slave stations1 master station can be followed by a maximum of 32 slave stations
Protocol typeCANopen DS301standard protocol
Support functionsSupports automatic starting of CANopen Manager
Supports optional slave polling
Support to start slave stations
Support NMT
Support synchronous production
Support synchronous consumption
Support heartbeat generation
Support activation time creation
Transmission rate(kbit/s)10008005002501255025
Maximum length(m)255010025050010002500
IsolationCommunication port isolation


Thin PLC master control unit requirements table 4- user program elements

Thin
Basic instruction set CTH300-H Basic instruction set 
Programming softwareMagicworks PLC V2.00 and above
Programming port1*RS485 port
1*Ethernet port
1*USB port
On-line programming Support
Programming languageStatement table STL Ladder diagram LAD
FB/FC/DB functionSupport
Accumulators4
Timer2048
Counter 2048



Installation

Power interface definition

4pin terminals spaced at 3.81mm apart

Symbol

Signal definition

312.png 

L+

+24V power

M

+24V power ground

 

Ground

--

--


USB interface definition

USB port

No.

Signal

Signal definition

313.png

1

V_BUS

+5V power

2

Data-

Data-

3

Data+

Data+

4

GND

Ground


EtherNET interface definition

RJ45 port

No.

Signal

Signal definition

314.png 

1

TX+

Positive end of data transmission

2

TX-

Negative end of data transmission

3

RX+

Positive end of data transmission

4

TERM

--

5

TERM

--

6

RX-

Negative end of data transmission

7

TERM

--

8

TERM

--

Shell

PE

Shell ground

Green indicator

As an indication of EtherNET connection status

Yellow indicator

As an indication of EtherNET connection status


RS485 interface definition

Port0,use 2pcs of 3pin terminals spaced at 3.81mm apart

6pin terminals 

Signal

Signal definition

315.png 

A0

PORT0 RS485 signal A

B0

PORT0 RS485 signal B

SG

PORT0 RS485 signal ground

A0

PORT0 RS485 signal A

B0

PORT0 RS485 signal B

SG

PORT0 RS485 signal ground


Dial switch definition

Dial switch

Symbol

Dial direction

Signal definition

316.png 

RUN

Up

System operation

STOP

Down

System halt


Swivel 5 times in 3 seconds

Reset the IP configuration (once from run-> STOP and once from stop-> RUN)


DIP dial

No.

Symbol

Signal definition

Note

317.png 

1

Term-PORT0

Terminal resistance switch 1(PORT0)

ON:with terminal resistance

OFF:without terminal resistance

2

Term-PORT1 (H35-00)

Terminal resistance switch 2(PORT1)

ON:with terminal resistance

OFF:without terminal resistance

NC (H36-00/H36-01)

--

--

3

RMC-SW

Remote control switch

ON:Remote control allow OFF:Remote control forbid



Return

Follow us

9F, Block A Building 6, Shenzhen International Innovation Valley, Dashi 1st Road, Nanshan District, Shenzhen

400-700-4858
0755-86226822

market@co-trust.com

Copyright COTRUST TECHNOLOGIES CO., LTD. 粤ICP备13051915号-2