C57-A3 CPU

Order No.:CTH3 C57-103S2

Specification: 32MB program data space,64KB power-off hold data,55M expansion bus,24VDC power supply,10 channels digital input,6*500KHZ high-speed counter,1*RS485 port,1*EtherNET port,1*USB port,,1*CAN port,1 *EtherCAT port; Maximum number of racks :4 (including local racks) Support up to 128 EtherCAT slave stations and support CODESYS programming platform SP18 version.

Product Description

Specification parameter  

Order number

32MB program data space, 64KB power down hold data, 55M expansion bus, 24VDC power supply, 10 channels digital input,6*500KHZ high-speed counter,1*RS485 port,1*EtherNET port,1*USB port,,1*CAN port,1 *EtherCAT port; support visual WebVisu, support OPC UA slave station, support EtherNet/IP master station, support MODBUS(RTU/TCP) master/slave, support single axis motion, interpolation, electronic gear and electronic CAM and other softmotion instruction set functions, Maximum number of racks :4 (including local racks) Support up to 128 EtherCAT slave stations and support CODESYS programming platform SP18 version.

CTH3 C57-103S2


Technical Spec
Product modelC57-A3
Order numberCTH3 C57-103S2
Physical characteristics
Size (WxHxD)34×115×101.6 mm
Power loss19.2W
Power supply characteristic
Rated input voltage24V DC
Input voltage range20.4V~28.8V DC
Input current  0.8A
Polarity reverse protectionYes
Bus power voltage +5V DC
Bus power current1.6A
LED indicator characteristics
24V Power indicator (green) On: 24VDC power supply is normal; Off: No 24VDC power supply.
SF Indicator (red)On: The system is faulty. Off: no error. 
BF indicator (red)On: The bus is faulty. Off: no error. 
RUN indicator (green) On: The system is running. OFF: The system stops.
STOP indicator (yellow)On: The system stops. Off: The system is running
Ethernet indicatorLink 1 indicator(Green)On: Connect; Off: No connection
SPEED 1 indicator(Yellow) On: 100Mbps; Off: 10Mbps
EtherCAT indicatorLINK 2 indicator(Green)  On: Connected; Off: Not connected
SPEED 2 indicator(Yellow) On: 100Mbps; Off: 10Mbps
IO indicator10.0~11.1(Green) ON: Signal input; Off: No signal input
Instruction performance
Bit instruction execution speed15ns
Floating point instruction execution speed45ns
Data storage specification Zone I 32K,Zone Q 32K,Zone M 512K
Internal memory 
User program space32M
Power off hold space64KB
Integrated communication function
Bus interfaceSupport
USB port1
EtherNET port1
RS485 port1
EtherCAT port1
CAN port1
EtherCAT port
Communication interface   1*EtherCAT port
Baud rate 100Mbps adaptive
Protocol type EtherCAT Interface protocol
Maximum cable length per section100m
Maximum number of sitesEach master supports a maximum of 128 EtherCAT slave stations
Support functionSupport distributed clock configuration, redundancy Settings
Support startup parameter configuration
Support PDO parameter configuration and mapping 
Support for bus cycle configuration, configure startup check vendor ID and product ID
IsolateYes
RS485 communication port
Number of communication interfaces 1,PORT0
Communication protocol Free port protocol (built-in MODbus-RTU protocol)
Free port baud rateRanges from 1.2Kbps to 115.2Kbps
Maximum cable length per sectionUse isolation repeater: 1000m(115.2Kbps)
                                          1200m(38.4 kbps)
Isolation repeater not used: 50m
Maximum number of sites32 stations per segment, 126 stations per network.
Isolate Communication port isolation
CANopen port
Communication interfaceCANopen
Protocol type 32
Protocol type CANopen DS301 standard protocol
Support functionSupport automatic start CANopen Manager 
Support Optional slave polling
Support starting the slave station
Support NMT 
Support synchronous production
Support synchronous consumption
Support heartbeat generation 
Support activation time creation
Transmission rate (kbit/s)10008005002501255020
Maximum length (m)255010025050010002500
IsolateCommunication port isolation
EtherNET communication port
Communication interface  1*EtherNET port
Baud rate 10/100Mbps adaptive
Protocol type CODESYS custom protocol, based on UDP and TCP(Ethernet programming and CPU support
Maximum cable length per section100m
Maximum number of connections for a siteUDP supports a maximum of 16 connections
IsolateCommunication port isolation
Programming Software 
Programming packageCODESYS V3.5 (SP18 version)
Programming language  Programming language according to IEC61131-3: CFC/FBD/LD/IL/ST/SFC
Protection function
Power supply protectionThe power supply terminal provides reverse protection and surge absorption functions
Interface protectionLightning protection for communication ports
Local I/O scalability
Maximum number of racks4
Maximum number of modulesHost rack: 11 (power module, CPU, trunk module, 8 signal modules)
Slave rack: 10 (power module, trunk module, 8 signal modules)
Remote I/O expansion capability
CAN extended maximum number of master stations1
CAN maximum number of slave stationsEach master station connects to a maximum of 32 CAN slave stations. 
EtherCAT maximum number of extended slavesUp to 128 EtherCAT slave modules , each EtherCAT slave module has a maximum of 8 signal modules
Supports motion control function
Motion control function  Do not support SoftMotion and CNC
Real-time clock
Power off hold spaceThe power failure holding time is about 112 hours (typical value), and the power failure holding time can reach at least 1 year after the external battery is connected
Precision Monthly deviation <60 seconds
Digital input characteristics
Native integrated IO points10
Input type  Drain type/source type
Rated voltage24V DC
Input voltage range 20.4~28.8V DC
Surge voltage 35V DC for 0.5s
Logic 1 Signal (min)15 VDC,2.5mA
Logical 0 signal (Max)5 VDC,1mA
Connect 2-wire Proximity Switch Sensor (BERO)1mA (maximum allowable leakage current)
Input filteringConfigurable, supporting 0.2us, 0.4us, 0.8us, 1.6us, 3.2us, 6.4us, 12.8us, 0.2ms, 0.4ms,0.8ms, 1.6ms, 3.2ms, 6.4ms, 12.8ms, default is 6.4ms
Isolation (field vs. logic) 500V AC,1minute
Simultaneous connected input10
Maximum cable length per section500 m (standard input)
Shield50m (high speed counter input)
Unshielded  300 m (standard input)
Pulse capture input10
High count counter Total6
Single-phase6×500KHz
Two-phase4×250KHz


Installation

C57-A3接口说明.jpg


Power interface definition


4 detachable terminals (spacing 3.50mm)

Symbol 

 Signal definition

图片3.png 

L+

24V power supply positive

M

24V power supply negative

图片11.png

24V power supply GND

--

--




USB interface definition

USB interface  

Bit number

Signal

Signal definition

图片4.png 

1

V_BUS

+5V power supply

2

Data-

Data negative

3

Data+

Data positive

4

GND

GND


EtherNET/EtherCAT interface definition

Dual network-port interface

Bit number

Signal

Signal definition

图片5.png

1

TX+

Data sending end

2

TX-

Data sending negative end

3

RX+

Data receiving terminal

4

TERM

--

5

TERM

--

6

RX-

Data receiving negative end

7

TERM

--

8

TERM

--

Connector housing

PE

Casing grounding


RS485/CAN Communication interface definition

Single port interface

Bit number

Signal

Signal definition

图片6.png

1

CAN_H

Data sending positive end

2

CAN_L

Data sending negative end

3

--

--

4

A0

RS485 signal A

5

B0

RS485 signal B

6

--

--

7

CAN_GND

CAN/RS485 signal GND

8

--

--

Connector housing

PE

Casing grounding


System running DIP switch definition

System run switch

Symbol


Dip direction

Signal definition

图片8.png 

RUN

UP

System operation

STOP

Down

System stop


Installation specification

1. Use DIN35 standard guide rail.

2. Installation size diagram:

Each C5X-10 motion controller has mounting holes, which can be easily installed on the backplane. Figure 3-2 shows the installation dimensions.

C57-A3尺寸图.jpg

Figure C5X-10 motion controller and installation dimensions


Return