- Product Description
-
Order Data
Model No.
Specification
Order No.
H35-00
CTH300-H standard CPU, 192KB PM, 512KB DM,16KB data stored when power down, 2 PPI/Free port, 1 EtherNET port, 1 USB port.
CTH3 H35-000S1
H36-00
CTH300-H standard CPU, 256KB PM, 1MB DM,32KB data stored when power down, 1 PPI/Free port, 1 EtherNET port,1 EtherCAT port, 1 USB port.
CTH3 H36-000S1
H36-01
CTH300-H standard CPU, 256KB PM, 1MB DM,32KB data stored when power down, 1 PPI/Free port, 1 EtherNET port,1 EtherCAT port, 1 USB port.(Recommend)
CTH3 H36-001S2
- Technical Spec
-
Performance Parameters
Physical features
Dimension(W×H×D)
34×115×101.6 mm
Power dissipation
19.5W
Power supply features
Rated input voltage
24V DC
Input voltage range
20.4~28.8V DC
Input current
0.8A
Reverse polarity protection
Yes Bus power supply voltage
+5V DC
Bus supply current
1.6A
LED indicator characteristics
24V power indicator (green)
On: 24VDC power supply is normal, off: no 24VDC power supply
SF indicator (red)
On: system failure, off: no error
BF indicator (red)
On: bus failure, off: no error
FRCE indicator (yellow)
On: items are forced, Off: no items are forced.< note > can also be controlled via the scrapers command.
RMC indicator (green)
On: CPU has successfully communicated with the remote server (dial switch 3 is ON and Ethernet port parameters have been configured correctly)
Off: CPU fails to communicate with the remote server or disallows communication with the remote server (allows and disallows communication with the server via dialing switch)
Run indicator (green)
On:system runs, off: the system stops
STOP indicator(orange)
On: system stops; Off: system runs
Ethernet indicator
Green
Flicker: connected, out: unconnected
Yellow
On:100Mbps,Off:10Mbps
Expand I/O capabilities
Maximum number of racks of 1CPU
4
Maximum number of modules supported per rack
Support up to 8 modules except power, CPU, relay module
Function category
Feature
Describe
Communication function
Bus interface
Provides an extension module interface
USB port
Provide a USB main device interface
Standard Ethernet interface
1 Ethernet interface is provided
® supports Ethernet programming;
® supports UDP_PPI protocol: network read and write operation between CPUs (instruction mode UDPNETW/UDPNETR or instruction wizard mode);
® supports Modbus_TCP protocol;
RS485 port
H35-00:2*RS485 port
H36-00/H36-01:1*RS485 port
EtherCAT port
H35-00:None
H36-00/H36-01:1*EtherCAT port
CANopen port
H35-00/H36-00:None
H36-01:1*CANopen port
Storage capabilities
Program memory
H35-00:192KB;H36-00/H36-01:256KB
Data storage
H35-00:512KB;H36-00/H36-01:1MB
Power down to maintain data
H35-00:16KB;H36-00/H36-01:32KB
Expand I/O capabilities
Expand function
Maximum expansion of 32 I/O modules (4 racks, 8 modules per rack)
Isolation function
Power supply isolation
Isolation between external power and system power
Communication isolation
EtherNET、EtherCAT、RS485、CANopen isolation
Protection function
Power protection
Power supply end provides reverse connection protection function and surge absorption function
Interface protection
Communication port lightning protection
Programming function
Programming function
MagicWorks PLC provides LAD ladder diagram, instruction list STL two programming languages, programming software support Chinese/English.
Run switch
RUN/STOP
Reset IP configuration by flipping the switch five times within 3 seconds
(RUN from run-> STOP, RUN from stop-bbb>
PORT0:RS485 port
Number of communication ports and protocols
RS485 port(switchable PPI and free port protocol)
Communication baud rate
PPI/MPI:9.6Kbps、19.2Kbps、187.5Kbps
Free port :1.2Kbps~115.2Kbps,built-in Modbus master/slave function
Maximum cable length per segment
Use isolation repeater: 1000m (187.5kbps)
1200m(38.4Kbps)
No isolation repeater: 50M
Maximum number of stations
Each segment with 32 stations and each network with 126 stations
Point to point (PPI main station mode)
Yes (NETR/NETW), each instruction is up to 200 bytes read/write, 8 read/write instructions are allowed at a time
MPI connection
A MPI slave station can connect up to 8 MPI masters
Isolation
Communication port isolation
RJ45 port
Communication protocol
H35-00
H36-00/H36-01
H36-01
PPI/MPI、 free port (Modbus RTU)
EtherCAT
CANopen
Communication baud rate
PPI/MPI:9.6Kbps、19.2Kbps、187.5Kbps
100Mbps
20Kbps~1Mbps
Free port:1.2Kbps~115.2Kbps
Maximum cable length per segment
Use isolation repeater: 1000m (187.5kbps)
1200m(38.4Kbps)
No isolation repeater: 50M
100m connection
Maximum 2500 m (20Kbps)
Minimum 25m (1Mbps)
Refer to CANopen communication port
Maximum number of stations
Each segment with 32 stations and each network with 126 stations
No limit Each master station support a maximum of 32 slaves
Point to point (PPI main station mode)
Yes (NETR/NETW), each instruction is up to 200 bytes read/write, 8 read/write instructions are allowed at a time
--
--
MPI connection
A MPI slave station can connect up to 8 MPI masters
--
--
Isolation
Communication port isolation
EtherNET port
Communication port
1*EtherNET port
Baud rate
10/100Mbps adaptive
Protocol types
Support UDP_PPI protocol, Modbus_TCP /IP master and slave protocol, support Socket free programming, support Ethernet programming and Ethernet communication between CPU
Maximum length of each cable
100m directly connected
Maximum number of connections per site
UDP_PPI supports a maximum of 8 connections, modbus_TCP supports a maximum of 32 connections, Socket supports a maximum of 4 connections, 2 UDP, 2 TCP
Quantity of user data Up to 200 bytes for UDP_PPI transfer,
Up to 240 bytes for ModBus_TCP transmission,
A maximum of 512 bytes are used for Socket transmission
DHCP function
Support Remote monitoring/programming
Support Isolation
Communication port isolation
CANopen port
Communication port
--
1*CAN port
Maximum number of slave stations
1 master station can be connected maximum of 32 slave stations
Protocol types
CANopen DS301standard protocol
Support functions
Supports automatic starting of CANopen Manager
Supports optional slave polling
Support to start slave stations
Support NMT
Support synchronous production
Support synchronous consumption
Support heartbeat generation
Support activation time creation
Transmission rate(kbit/s)
1000
800
500
250
125
50
20
Maximum length(m)
25
50
100
250
500
1000
2500
Isolation
Communication port isolation
- Installation
-
Power interface definition
4pin terminals spaced at 3.81mm apart
Symbol
Signal definition
L+
+24V power
M
+24V power ground
Ground
--
--
USB interface definition
USB port
No.
Signal
Signal definition
1
V_BUS
+5V power
2
Data-
Data-
3
Data+
Data+
4
GND
Ground
EtherNET interface definition
RJ45 port
No.
Signal
Signal definition
1
TX+
Positive end of data transmission
2
TX-
Negative end of data transmission
3
RX+
Positive end of data transmission
4
TERM
--
5
TERM
--
6
RX-
Negative end of data transmission
7
TERM
--
8
TERM
--
Shell
PE
Shell ground
Green indicator
As an indication of EtherNET connection status
Yellow indicator
As an indication of EtherNET connection status
CAN interface definition
RJ45 port
No.
Signal
Signal definition
1
CAN_H
Positive end of data transmission 2
CAN_L
Negative end of data transmission 3
--
--
4
--
--
5
--
--
6
--
--
7
CAN_GND
CAN Gound
8
--
--
Shell PE
Shell ground Green indicator As an indication of CAN connection status
Yellow indicator As an indication of CAN connection status
RS485 interface definition
Port0,use 2pcs of 3pin terminals spaced at 3.81mm apart
6pin terminals
Signal
Signal definition
A0
PORT0 RS485 signal A
B0
PORT0 RS485 signal B
SG
PORT0 RS485 signal ground
A0
PORT0 RS485 signal A
B0
PORT0 RS485 signal B
SG
PORT0 RS485 signal ground
Dial switch definition
Dial switch
Symbol
Dial direction
Signal definition
RUN
Up
System operation
STOP
Down
System halt
Swivel 5 times in 3 seconds
Reset the IP configuration (once from run-> STOP and once from stop-> RUN)
DIP dial
No.
Symbol
Signal definition
Note
1
Term-PORT0
Terminal resistance switch 1(PORT0)
ON:with terminal resistance
OFF:without terminal resistance
2
Term-PORT1 (H35-00)
Terminal resistance switch 2(PORT1)
ON:with terminal resistance
OFF:without terminal resistance
NC (H36-00/H36-01)
--
--
3
RMC-SW
Remote control switch
ON:Remote control allow OFF:Remote control forbid