CPU H212(CTH2 212-1BD20-0X16 )

Order No.:CTH2 212-1BD20-0X16

Specification:32KB program space/8KB data space 1×Ethernet port (100M,support MiCo remote) 1×RS485 port ( PPI, MODBUS_RTU ) Supports 2×100KHz high-speed source output Support Trace tracing Support analog expansion board (2AI 1AO or 4AI 2AO) (Not support RS485/CAN expansion board & module expansion)

Product Description

Order Date

Products data

Order No.

 

CTH200  series CPU

CPU

H212

32KB program space/8KB data space

1×Ethernet port (100M,support MICO remote)

1×RS485 port ( PPI, MODBUS_RTU )

Supports 2×100KHz high-speed source output

Support Trace tracing

Support analog expansion board (2AI 1AO or 4AI 2AO)

(Not support RS485/CAN expansion board and module expansion)

220VAC, 8DI/8DO (relay output, 2A),

Support 4×50k single-phase/1×30k dual-phase HSC.

CTH2 212-1BD20-0X16


Technical Spec
CPU H212
SpecificationCTH2 212-1AD20-0X16CTH2 212-1BD20-0X16
8DI/8DO Transistor8DI/8DO Relay
Overall Characteristic
Dimensions (W × H× D)96×72×80mm
Power Dissipation5W7W
Program memory24KB+8KB(Confidential Database)
Data memory8KB
Power-off memory8KB
Data PreservationFlashROM(Permanent Preservation)
The maximum number of expansion modulesDo not support
Maximum digital quantity12DI/12DO(Adapt through the new expansion board)
Maximum analog quantity4AI/2AQ(Adapt through the expansion board)
Power Characteristics
Rated input voltageDC24VAC220V
Input voltage range20.4V~28.8V DC85 V~265V AC
Impact current6A @ 28.8VDC8A @ 264VAC
Isolation (field and logic)NoAC power supply:1500V AC
Hold time (power off)More than 10ms10ms/20ms以上,120/240V AC
+5V Power outputExpansion busDo not support
BD expansion board bus200mA(With switch control)
Communication10mA 100R resistance
Sensor +24V power outputNoVoltage Range:20.4~28.8V DC
Rated Current:300mA
Ripple noise: peak-to-peak less than1V (<10MHz)
Isolation (sensor and logic) : Not isolated
Power AlarmAlarm for insufficient power supply of 15V, alarm bit SM195.1
Conventional Features
Total number of timers1ms4
10ms16
100ms236
Counter256
Accumulator4
Memory storage bit256 Bit
The retention time of memory storage bits after power failurePermanent Preservation
Local storage area(L)64 bytes independent
Sequential control relay(S)256 Bit
Time interruption2*1ms resolutions
Edge interruption4 rising edges and/or 4 falling edges(I0.0,I0.1,I0.2,I0.3)
Execution time of Boolean operations≤0.15µs
Floating-point operation execution time≤6.2µs
Real-time clockBuilt-in, the clock does not support power-off retention at the factory, but a button battery can be configured
The number of BD expansion board interfaces1,supporting analog quantity expansion board
System indicator lightLINK/ACT Indicator light (green)ON:Connect
Blinking:Transmit
OFF:Disconnect
Remarks:Blinking:Flash once every 200 milliseconds.
RMC  Indicator light (green)ON:The CPU has successfully communicated with the remote server (the parameters of the Ethernet communication port have been correctly configured)
OFF:Communication with the remote server failed or communication with the remote server is prohibited
SF/DIAG Indicator light (red)ON:System failure.
OFF:No system failure.
RUN Indicator light (green)ON:Run
OFF:Stop
STOP Indicator light (yellow)ON:Run
OFF:Stop
Digital input indicator light (green)ON:Signal input
OFF:No signal input
Digital output indicator light (green)ON:Signal input
OFF:No signal input
Run switchRUN/STOP
External battery interfaceDo not support,Configurable button battery, alarm position SM195.0
Programming cardSupport
Memory cardDo not support
Motion control functionSupports single-axis motion control
Functions such as positioning, speed and homing
No
Integrated communication function (PPI/ free port)
Communication interface1*communication port (PPI slave station and free port mode can be switched)
PORT0:PPI/ Free Port, standard RS485 level
PPI baud Rate(baud)9.6k、19.2k and187.5k
Free port baud rate(baud)1.2k ~ 115.2k,with built-in Modbus RTU master/slave station functions
Maximum number of sitesEach section has 32 stations, and each network has 126 stations
The maximum number of master stations32
Point-to-point (PPI master Station mode)Yes (NETR/NETW), each instruction can read/write up to 200 bytes at most, and up to 8 read/write instructions are allowed at the same time
MPI connection1*MPI slave station can connect to a maximum of 8*MPI master stations
Protocol typeConnect to the PC to download/upload/monitor
Connect to the host computer and program or debug through the human-machine interface
Standard MODBUSASCI/RTU communication, free format communication
The number of protocol connections and the number of transmissionsModbus_RTU master/slave: Data transmission can only be performed once at a time, with a total of 240 bytes
Each paragraph
Maximum cable length
Use an isolation repeaterAt a baud rate of 187.5k, it is 1000 meters; at 38.4k, it is 1200 meters
Do not use an isolation repeater50 m
Ethernet communication function
Communication interface1*Standard Ethernet port
Communication standardCompliant with IEEE802.3
Transmission speed10Mbps/100Mbps adaptive
Adaptive cross-connectionSupport
Hardware interfaceRJ45
Protocol typeUDP,TCP/IP
Configuration methodDownload the network block through the programming software MagicWorks PLC for configuration
Protocol typeUDP_PPI protocol
Modbus TCP/IP master-slave protocol
S7 master-Slave protocol
Socket
Support Ethernet communication between PLCS
Support MiCo Ethernet programming
Maximum number of connections8*UDP/PPI without master-slave distinction
8*TCP/Modbus without master-slave distinction
16*Socket connections, 8 for UDP and 8 for TCP
8 for S7 protocol Regardless of master-slave station
Maximum single data transmissionUDP/PPI each operation up to 200 bytes
Each operation of TCP/Modbus is up to 240 bytes at most
A Socket can operate at most 512 bytes each time
The S7 protocol can operate at a maximum of 200 bytes per operation
Length of communication cable100M, cable type: CAT5e standard or above
IsolationCommunication port isolation
IP address reset functionSwitch the operation switch 5 times in a row within 2 seconds
Upgrade the firmware functionOnly serial port upgrade is supported
I/O Characteristic
The number of digital input points of this machine8
Input typeLeak type/source type
The digital output points of this machine8
Output typeSolid- MOSFET, source typeRelay - dry contact
Digital input characteristics
Rated voltage24 VDC
Input voltage range20.4~28.8 VDC
Surge voltage35 VDC,Last for 0.5s
Logic 1 Signal (Minimum)15V DC,>2.5mA
Logic 0 signal (maximum)5V DC,<1mA
Connect the 2-wire proximity switch sensor (BERO)
Allowable leakage current (Maximum)
1mA
Input filteringConfigurable, supporting 3.2ms and 6.4ms, with a default of 6.4ms
Isolation (on-site and logical) isolation group500 VAC,1 minute
Simultaneously connected input8
Maximum cable lengthShielded: 500 meters (standard input), 50 meters (high-speed counter input)
Unshielded: 300 meters (standard input)
High-speed counting characteristic
Pulse capture input8
High-speed Counter
High-speed CounterTotality4
Single-phase Counter4×50KHz,Support HSC0、HSC1、HSC4 and HSC5,Do not support HSC2 and HSC3
AB phase Counter1×30KHz,Support Mode 9,HSC0
Input point configuration of the high-speed counter
HSC input signalModeInterrupt descriptioninput point

HSC0I0.0I0.1


HSC1I0.6I0.7


HSC4I0.3



HSC5I0.4


0A single-phase counter with internal direction controlClock--

9A/B phase orthogonal counterClock AClock B

Digital output characteristics
Output rated voltageDC:24VDC:24V,AC:110V/220V
Output voltage rangeDC:5~30VDC:5~30V,AC:5~250V
Output current (maximum)0.5A2A
Surge current8A,100ms5A,4s@10% Duty Cycle
Lamp load5WDC:30W /AC:200W
Conduction resistanceTypical value 0.3Ω,Maximum 0.6ΩMaximum 0.2Ω
Output delay (maximum)
Disconnect to connect/Connect to disconnect
Disconnect to connect:
2us(Q0.0,Q0.1),---15us(Other)
Disconnect to connect:Maximum10ms
Connect to disconnect:
10us(Q0.0,Q0.1),---130us(Other)
Connect to disconnect:Maximum10ms
Mechanical life (no-load)No10,000,000
Contact life (rated load)No100,000
Simultaneously connected output8
Two outputs in parallelDo not supportYes, only when the same group is output
Maximum cable lengthShielded500 m
Unshielded150 m
High-speed counting characteristic
Pulse output2*50KHZ motion control output (Note: Modes cannot be used simultaneously)Do not support
Support pulse librarySupport the motion control library motion_ctrl_libDo not support
Corresponding application pointsPulse point:Q0.0/Q0.1
Direction point:Q0.2/Q0.3
Do not support
Special functionThe direction point can be chosen not to be usedDo not support


Installation

Size:

H212尺寸.png


Wiring diagram

H212接线图-英文.png