product_Banner
CTF220 Converter

CTF220 Frequency Converter

CTF220 series inverter adopt speed sensorless vector control technology, the product has excellent driving performance and control functions; the product has rich hardware configuration, powerful software functions, and has a greater improvement in ease of use and reliability, which can better meet the different needs of various industrial control occasions.

Order No.:

Specification: CTF220 series 0.75~18.5kw built-in standard braking unit, 22~90kw selected built-in braking unit, the whole series of independent duct design, improve product reliability and performance, enhance product competitiveness.

Product Description

Applications

Machine tool、Cable machinery、Petrochemical industry 、Textile industry、Food packaging、Eluting equipment、Centrifuge etc


CTF220 Series Model and Technical Data

TypeRated CapacityRated InputRated Output Current(A)Adapter
(KVA)Current (A)Motor(KW)
Single-phase power supply   200~240V   50/60Hz
CTF220-2T0.71.58.240.75
CTF220-2T1.531471.5
CTF220-2T2.24239.62.2
Three-phase power supply    380~480V   50/60Hz
CTF220-4T0.7G/1.5P1.5/33.4/52.1/3.80.75/1.5
CTF220-4T1.5G/2.2P3/45/5.83.8/5.11.5/2.2
CTF220-4T2.2G/3.0P4/4.95.8/8.05.1/6.82.2/3.0
CTF220-4T3.0G/4.0P4.9/5.98.0/10.56.8/9.03.0/4.0
CTF220-4T4.0G/5.5P5.9/8.910.5/14.69/134.0/5.5
CTF220-4T5.5G/7.5P8.9/1114.6/20.513/175.5/7.5
CTF220-4T7.5G/11P11/1720.5/2617/257.5/11
CTF220-4T11G/15P17/2126/3525/3211/15
CTF220-4T15G/18.5P21/2435/38.532/3715/18.5
CTF220-4T18.5G/22P24/3038.5/46.537/4518.5/22
CTF220-4T22G/30P30/4046.5/6245/6022/30
CTF220-4T30G/37P40/5762/7660/7530/37
CTF220-4T37G/45P57/6976/9275/9137/45
CTF220-4T45G/55P69/8592/11391/11245/55
CTF220-4T55G/75P85/114113/157112/15055/75
CTF220-4T75G/90P114/134157/180150/17675/90
CTF220-4T90G/110P134/160180/214176/21090/110
CTF220-4T110G/132P160/192214/256210/253110/132

CTF220 Series Naming Rules

CTF220-11.jpg



Technical Spec

 CTF220 series Specifications


ItemSpecifications
Basic functionsMaximum frequencyVector control: 300.00Hz
V/F control: 3200Hz
Carrier frequency0.5kHz-16kHz, The carrier frequency can be adjusted automatically based on the load features.
Input frequency resolutionDigital setting: 0.01Hz
Analog setting: maximum frequency × 0.025%
Control modeOpen-loop vector control (SVC)
Closed-loop vector control (FVC)30KW and above
V/F Control
Start-up torqueG type: 0.5Hz/150% (SVC), 0Hz/180% (FVC)
P type: 0.5Hz/100%.
Speed range1:100 (SVC)1:1000(FVC)
Steady speed accuracy±0.5%(SVC)±0.02%(FVC)
Torque control accuracy±5%(FVC)
Overload capacityG type: 150% rated current 60s; 180% rated current 3S        P type: 120% rated current 60s; 150% rated current 3S
Automatic torque liftingManual torque lifting 0.1%-30.0%.
Three ways of V/F curveStraight-line type;
Multi-point type;
Ramp mode  Straight-line ramp or S-curve ramp, Four groups of acceleration /deceleration time with the range of 0.0s-6500.0s
DC braking0.00Hz - maximum output frequency,
Braking time: 0.0s - 36.0s
Braking action current value: 0.0% - 100.0%.
JOG controlJOG frequency range: 0.00Hz-50.00Hz,
JOG acceleration / deceleration time: 0.0s-6500.0s
On board multiple preset speedsIt implements up to 16 speeds via the simple PLC function or combination of DI terminal states.
Built-in PIDIt realizes process-controlled closed-loop control system easily.
Automatic voltage adjustment (AVR)It can keep constant output voltage automatically when the main voltage changes.
Torque limitation and control It cam limit the torque automatically and prevent frequent over current tripping during the running process.
Individualized functionsSafety self-inspection of power-on peripheral equipmentIt can realize the safety detection of peripheral equipment such as grounding, short circuit and so on.
Over-voltage and over-loss speed controlAutomatic limit of current and voltage during operation to prevent frequent over-current and over-voltage tripping
Fast current LimitMinimizing overcurrent fault and protecting frequency converter in normal operation
Common DC bus functionIt can realize common DC bus functions of multiple frequency converters.
QUICK keyUser-defined shortcut menu
MF.K keyProgrammable key: command channel switching/forward and reverse running/JOG running function selection
Textile swing frequency controlGiven length control function
Timing controlTiming control function: setting time range 0h-65535h
Running channelRunning command sourcesThree channels: operation panel, control terminal and serial communication port .They can be switched over between these sources in various ways.
Frequency sources       There are total 10 of frequency sources, such as digital setting, analog voltage setting, analog current setting,pulse setting and serial communication port setting. They can be switched over these sources in various ways.
Auxiliary frequency command10 kinds of auxiliary frequency instructions. It can realize auxiliary frequency fine adjustment and frequency synthesis flexibly.
Input terminalSeven digital input terminals (6 digital inputs within 22KW), of which X5 can be used for high-speed pulse input.
Compatible with active PNP or NPN input mode.Two analog input terminals can be used for voltage or current input.
Output terminal①1 high-speed pulse output terminal DO (optional open collector type), 0 KHz-100 KHz square wave signal output
It can realize the output of set frequency, output frequency and other physical quantities; 
②3 digital output terminals(>30KW);
③2 relay output terminals;
④2 analog output terminals, 0/4mA-20mA or 0V-10V, It can realize the output of set frequency, output 
frequency and other physical quantities.
Display and keyboardLED displayDisplay monitoring parameters, output frequency, set frequency, bus voltage, etc.
Protection FunctionShort circuit detection , input and output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection , overheat protection and overload protection
Optional parts  Brake assembly
AmbientInstallation locationIndoor ,free from direct sunlight, dust-free, corrosive gases, combustible gases, oil smoke, vapour, drip or salt, etc.
Altitude<1000m
Ambient temperature-10°C~+40°C (ambient temperature is 40°C~50°C , please derate to use)
HumidityLess than 95 k% RH, no water droplet condensation
Vibrationless than 5.9m/s 2 (0.6g)
Storage temperature-20℃~+60℃
IP level IP20
Pollution gradePD2
Power distribution system  TN,TT



Installation

1.1 CTF220 Product Profile

A: 22kW Outline Size and Installation Size

CTF220-31.png


B: 30kW~110kW Outline Size and Installation Size

CTF220-32.png


1.2 Profile and Installation Hole Size


Shell codeModelInstallation Hole Position (mm)Dimension (mm)Installation Diameter (mm)Weight(kg)
A1/A2BHH1WD
Z2CTF220-2T0.781/81162162172921524.51.4
CTF220-2T1.5
CTF220-2T2.2
CTF220-4T0.7G/1.5P
CTF220-4T1.5G/2.2P
CTF220-4T2.2G/3.0P
CTF220-4T3.0G/4.0P
CTF220-4T4.0G/5.5P
Z3CTF220-4T5.5G/7.5P98/98208207219109172.55.52.1
CTF220-4T7.5G/11P
Z4CTF220-4T11G/15P119/1192502502611301825.53.4
CTF220-4T15G/18.5P
Z5NCTF220-4T18.5G/22P167/177282280293190199∅5.55.7
CTF220-4T22G/30P5.9
Z6NCTF220-4T30G/37P210/200410390426250210913.5
CTF220-4T37G/45P
Z7NCTF220-4T45G/55P266/266473450492300236918.35
CTF220-4T55G/75P18.85
ENCTF220-4T75G/90P230/2305365005553202301024.8
FNCTF220-4T90G/110P320/3206115686344102401235.5
CTF220-4T110G/132P36.2

1.3 External Keyboard Size

Only Z2, Z3, Z4 shell standard with CTF-KB 220 keyboard, other shells are standard with CTF-KB 221 native keyboard.

1、CTF-KB220 External Keyboard Size(Opening Size 72*53.5mm)

CTF220-41.png


2、CTF-KB220A Keyboard shell Size(Opening Size 80.5*65.5mm)

CTF220-42.png


3、CTF-KB221 External Keyboard Size(Opening Size63.5*95.5mm)

CTF220-43.png


4、CTF-KB220A Keyboard shell Size(Opening Size 77.5*123mm)

CTF220-44.png



2.  Typical Wiring Diagram

CTF220-5.png


Return

Follow us

9F, Block A Building 6, Shenzhen International Innovation Valley, Dashi 1st Road, Nanshan District, Shenzhen

400-700-4858
0755-86226822

market@co-trust.com

Copyright COTRUST TECHNOLOGIES CO., LTD. 粤ICP备13051915号-2